no code implementations • 19 Mar 2024 • Jingwei Zhang, Lauren Swinnen, Christos Chatzichristos, Victoria Broux, Renee Proost, Katrien Jansen, Benno Mahler, Nicolas Zabler, Nino Epitashvilli, Matthias Dümpelmann, Andreas Schulze-Bonhage, Elisabeth Schriewer, Ummahan Ermis, Stefan Wolking, Florian Linke, Yvonne Weber, Mkael Symmonds, Arjune Sen, Andrea Biondi, Mark P. Richardson, Abuhaiba Sulaiman I, Ana Isabel Silva, Francisco Sales, Gergely Vértes, Wim Van Paesschen, Maarten De Vos
The combination of wearable EEG and EMG achieved overall the most clinically useful performance in offline TCS detection with a sensitivity of 97. 7%, a FPR of 0. 4/24 h, a precision of 43. 0%, and a F1-score of 59. 7%.
1 code implementation • 29 Apr 2020 • Simon Van Eyndhoven, Patrick Dupont, Simon Tousseyn, Nico Vervliet, Wim Van Paesschen, Sabine Van Huffel, Borbála Hunyadi
EEG-correlated fMRI analysis is widely used to detect regional blood oxygen level dependent fluctuations that are significantly synchronized to interictal epileptic discharges, which can provide evidence for localizing the ictal onset zone.